+86-312-6775656

Sinov transformatorini tanlash usuli va hisobga olinadigan omillar

Jan 10, 2022

Sinov transformatorini tanlashda, asosan, quyidagi jihatlar e'tiborga olinadi:


1) Test voltage. According to the requirements of the test product, first select a test transformer with a suitable voltage, so that the rated voltage Un of the high-voltage side of the test transformer is higher than the test voltage Us of the test product, that is, Un>Biz. Ikkinchidan, sinov transformatori tomonidan talab qilinadigan past-kuchlanish tomonidagi kuchlanish-joydagi quvvat manbai kuchlanishi va kuchlanish regulyatoriga mos kelishini tekshiring.


2) Test current. The rated output current In of the test transformer should be greater than the current Is required by the tested product, that is, In>Bu. Sinov mahsuloti uchun zarur bo'lgan oqim uning sig'imi bo'yicha baholanishi mumkin, Is=UswCx, bunda Cx sinov mahsuloti sig'imi va qo'shimcha sig'imni o'z ichiga oladi.


3) Sinov qobiliyati. Sinov transformatorining nominal oqimi va nominal kuchlanishiga ko'ra, sinov transformatorining quvvatini aniqlash mumkin, ya'ni P=UnIn.


According to the relevant test transformer standards, the voltage levels of my country's test transformers are: 5, 10, 25, 35, 50, 100, 150, 300kV, etc.; the capacity levels are: 3, 5, 10, 25, 50, 100, 150 , 200kVA, etc.


Kerakli sinov transformatorini hisoblash natijalari va tegishli standartlardan tanlash mumkin. Agar maxsus talablar mavjud bo'lsa, maxsus xususiyatlarga ega sinov transformatorlarini sinov uchun ishlab chiqaruvchi Wuhan Hezhong Electric kompaniyasidan buyurtma qilish mumkin.


Sinov transformatorini tanlash misoli


Misol uchun, tarqatish transformatorining kuchlanish darajasi va quvvati 10kV va 1000kVA, sinov mahsuloti asosan 10kV, shuning uchun 50kV va 5kVA sinov transformatorini tanlash mumkin. Sinov kuchlanishi 30 kV; Shu bilan birga, u 10kV izolyatorlar va yuqori{7}}kuchli elektr uzatish moslamalari sinovi (sinov kuchlanishi 42kV) va 10kV kabellarning doimiy sinovi (doimiy kuchlanish 60kV va mos keladigan AC) talablariga javob berishi mumkin. kuchlanish 42,83 kV).


Sinov quvvatiga kelsak, sinovdan o'tgan 10kV, 1000kVA transformator, zaryadlash paytida sig'imli oqim 3035kV sinov paytida taxminan 80110mA ni tashkil qiladi, chunki 35kVx110mA.<5kva, so="" 5kva="" can="" meet="" the="" requirements.="" another="" example="" is="" a="" 35kv,="" 2000~4000kva="" transformer,="" when="" the="" test="" voltage="" is="" 72~85kv,="" the="" capacitive="" current="" is="" about="" 150~260ma,="" 6000~8000kva="" is="" about="" 300~420ma,="" 10000kva="" is="" about="" 800~1000ma,="" etc.="" the="" capacity="" of="" the="" selected="" test="" transformer="" must="" be="" greater="" than="" the="" capacity="" corresponding="" to="" the="" above-mentioned="" test="" capacitor="" current.="" for="" routine="" test="" requirements,="" the="" capacity="" of="" the="" test="" transformer="" is="" 5%="" of="" the="" capacity="" of="" the="" tested="" product="" (power="">



So'rov yuborish