Parametr (namuna sifatida 200V/30A 220V/50A, 220V/80A 220V/100A oling)
Xususiyatlari | Parametrlar | |||
Yagona kuchlanish sinov turi | 2V/6V/12V | 2V/6V/12V | 2V/6V/12V | 2V/6V/12V |
Yagona kuchlanish sinov diapazoni | 2V:0-4V 6V:0-8V 12V:0-15V | 2V:0-4V 6V:0-8V 12V:0-15V | 2V:0-4V 6V:0-8V 12V:0-15V | 2V:0-4V 6V:0-8V 12V:0-15V |
Yagona kuchlanish o'lchamlari | 2V/6V:0.001V 12V:0.01V | 2V/6V:0.001V 12V:0.01V | 2V/6V:0.001V 12V:0.01V | 2V/6V:0.001V 12V:0.01V |
Butun o'rnatilgan kuchlanish sinov diapazoni | 0~290V | 0-290V | 0-290V | 0V -290V |
Butun o'rnatilgan kuchlanish o'lchamlari | 0.01V | 0.01V | 0.01V | 0.01V |
Kuchlanish sinovining aniqligi | 0,5 foiz | 0,5 foiz | 0,5 foiz | 0,5 foiz |
Bo'shatish diapazoni | 2 ~ 30A doimiy ravishda o'rnatilishi mumkin, 30A dan ortiq bizga qo'shimcha yuk kerak | 2 ~ 50A doimiy ravishda o'rnatilishi mumkin, 50A dan ortiq bizga qo'shimcha yuk kerak | 2 ~ 80A doimiy ravishda o'rnatilishi mumkin, 80A dan ortiq bizga qo'shimcha yuk kerak | 2 ~ 100A doimiy ravishda o'rnatilishi mumkin, 100A dan ortiq bizga qo'shimcha yuk kerak |
Doimiy zaryadsizlanish kuchlanish diapazoni | 180~280V | 180-280V | 180-280V | 180V -280V |
Bo'shatishni boshqarishning aniqligi | 0.1A | 0.1A | 0.1A | 0.1A |
Hozirgi sinov aniqligi | 1 foiz | 1 foiz | 1 foiz | 1 foiz |
Ish kuchlanishi | AC 220V±15 foiz
| |||
Radiatsiya | Havo sovutish | |||
Aloqa | RS485 Aloqa va SD karta aloqasi | |||
Displey | 7 dyuymli rangli LCD sensorli ekran | |||
Umuman xira. | 440 × 225 × 300 mm | 440 × 225 × 300 mm | ** | *** |
Og'irligi | <10,5 kg | <10,5 kg | ** | ** |