+86-312-6775656

HZJF-9041D Fourchannels qisman zaryadsizlanish sinov tizimi

Oct 25, 2023

HZJF-9041D Fourchannels qisman zaryadsizlanish sinov tizimi

 

Struktura tavsifi

Asbob ish stoli standart shkafi tuzilishi. Asbobning ishlash yuzasi ikki qismga bo'linadi: old panel va orqa panel. Har bir komponentning pozitsiyalari 2a va 2b-rasmda ko'rsatilgan

 

news-967-555

Shakl 2a HZJF-9041Qisman zaryadsizlanish detektori old panelining sxematik diagrammasi

news-899-539

Shakl 2b HZJF-9041Qisman zaryadsizlanish detektori orqa panelining sxematik diagrammasi

HZJF-9041DOld panel va orqa panel komponentlarining tavsifi

1. Sensorli ekran: o'lchangan PD to'lqin shakli, PD, sinov kuchlanishi, sinov chastotasi va boshqa parametrlarni ko'rsatish;

2. Quvvatni o'zgartirish tugmasi: yoqish uchun bir marta bosing; o'chirish uchun yana bosing;

3. Qisman deşarj kiritish: qisman zaryadsizlanishni o'lchash signali kiritish, HZJF-9041D to'rtta kanalga ega, signalga istalgan kanaldan kirish mumkin;

4. Yuqori kuchlanishli kuchlanish bo'luvchi, kuchlanish diapazoni: 150V;

5. Topraklama murvati: sinov paytida ishonchli topraklama talab qilinadi;

6. RS232 porti: ushbu ketma-ket port orqali qisman tushirish moslamasining parametrlari boshqa uskunalarga yuklanishi mumkin;

7. Tashqi quvvat manbai kiritish;

 

Asosiy texnik ko'rsatkichlar

1. Ekvivalent sig'im 6pF dan 250 mF gacha

2. Kanallar soni: To'rtta kanal

3. Oʻlchov diapazoni: 0.1pc-10000nc

4. Aniqlash sezgirligi va ruxsat etilgan oqim (1-jadvalga qarang)

 

 

YO'Q.

Tuning sig'im diapazoni

Sezuvchanlik (kompyuter)

(Muvozanatsiz zanjir)

Ruxsat etilgan oqimning samarali qiymati

Balanssiz zanjir

Balans davri

1

0-25-100pF

0.02

30mA

0.25A

2

25-100-400pF

0.04

50mA

0.5A

3

100-400-1500pF

0.06

120mA

1A

4

400-1500-6000pF

0.1

0.25A

2A

5

1500-6000-25000pF

0.2

0.5A

4A

6

0.006-0.025-0.1μF

0.3

1A

8A

7

0.025-0.1-0.4μF

0.5

2A

15A

8

0.1-0.4-1.5μF

1

4A

30A

9

0.4-1.5-6.0μF

1.5

8A

60A

10

1.5-6.0-25μF

2.5

15A

120A

11

6.0-25-60μF

5

25A

200A

12

25-60-250μF

10

50A

300A

7R

Qarshilik

0.5

2A

15A

Jadval 1. Aniqlash sezgirligi va kirish birligining ruxsat etilgan joriy qiymati

5. Elliptik skanerlash vaqt bazasi

(1) Chastotasi 50/60, 100, 150, 200, 400Hz

(2) Aylanish: birinchi vites sifatida 30 daraja va 120 daraja aylanishi mumkin

(3) Ishlash usuli: ellips sinus to'lqini to'g'ri chiziq

6. Displey birligi

10,1 dyuymli sig'imli sensorli ekran ishlatiladi.

7. Kuchaytirgich

(1) 3dB past chastotali fl: 10, 20, 40KHz ixtiyoriy

(2) 3dB yuqori chastotali fh: 80, 200, 300kHz ixtiyoriy

(3) Gain adjustment, rough adjustment 6, inter gear gain difference 20 ± 1dB, fine adjustment range >20db

(4) Ijobiy va salbiy impuls javobining assimetriyasi < 1dB

8. Vaqt oynasi

(1) Oyna kengligi: sozlanishi, 50Hz da 5 daraja ~ 170 daraja

(2) Deraza holati: har bir oyna 0 daraja ~ 170 daraja aylanishi mumkin

(3) Ikki vaqt oynasi alohida yoki bir vaqtning o'zida ochilishi mumkin.

9. Pulsning eng yuqori ko'rsatkichi

Sensorli ekranda 1 kasr (10 dona yoki undan ko'p), 2 kasr (10 donadan kam), xatolik: ± 3% (to'liq masshtabda) ko'rsatiladi.

10. Sinov kuchlanishining ko'rsatkichi

(1) Diapazon 150kV

(2) Input impedance: >1m Ω

(3) Displey: sensorli displey, 1 kasrli kasrni ko'rsatish

(4) Xato: ± 1%

11. Sinov chastotasini ko'rsatish

Xato: ± 1% dan kam

12. Nolinchi standart tizimi

Nol belgisi barcha ellips skanerlash chastotalariga mos keladi

13. Tuzilishi

(1) O'lchamlari: 370 mm (kenglik), 460 mm (chuqurlik), 215 mm (balandlik)

(2) Og'irligi: taxminan 12,5 kg

So'rov yuborish